Ebro EBI 16 Bowie Dick

Ensuring correct sterilisation of equipment in hospitals, veterinary and dental surgeries is critical to patient care.  Ebro provide a validation kit that logs temperatures at all parts of an autoclave and this EBI 16 -  SL 1520 starter kit is specifically designed for routine checks of steam sterilizers using the industry standard Bowie-Dick data logger that performs in accordance with the norms EN 285 / ISO 17665

  • Features
  • Specifications
  • Software
  • Documents

EBI 16 -  SL 1520 for routine checks of steam sterilizers with Bowie-Dick logger for steam sterilisers according to the norms EN 285 / ISO 17665

With the EBI 16 starter set you can start your electronic Bowie Dick Test immediately according to the norms DIN EN 285 and DIN EN 17665.

For routine checks of steam sterilizers and washer-disinfectors. The set contains:

1 x Bowie Dick Logger EBI 161 x Interface EBI IF 1501 x Software Winlog.med1 x Aluminium carrying case

Together with the evaluation software Winlog.med the new EBI 16 data logger forms an easy to use and very reliable electronic measurement system. With it a comprehensive routine control of steam sterilizers can be performed using an alternative Electronic Bowie Dick Test according to DIN EN ISO 11140-4. In addition to the review of the steam penetration, the relevant sterilization parameters are controlled.

• Reliable: clear, reproducible measurement results

• Accurate: high-resolution graphical cycle display

• Secure: digital data recording and storage

• Easy: to use and evaluate

Bowie Dick Test

The EBI 16 delivers clear results during daily checks of the air evacuation test and steam penetration test according to DIN EN 17665 and DIN EN 285.

Early warning system

The EBI 16 provides early identification of possible failures in steam-sterilizers. Even small quantities of residual air that doesn't lead to a failed Bowie Dick Test yet, are detected.

Vacuum check

The EBI 16 allows a reasonable vacuum check also for sterilizers without pressure display according to DIN EN 285.

Verification of sterilization parameters

The EBI 16 checks the sterilization parameters such as compensation time, hold time, sterilization temperature and sterilization time according to DIN EN 285.

Measuring range: 0°C ... +150°, 0 mbar ... 4.000 mbar
Accuracy: ± 0.1°C, ± 15 mbar
Resolution: 0.01°C, 1 mbar

Memory: 6750 measurement values
Measured variables: temperature, pressure


IP Rating: IP 68


Dimensions: 90 mm x 150 mm
Weight: 500 g
Certificate: Factory calibration certificate

For routine controls

Software (Standard-Software for the CSSD)

Product Description

• User-friendly

• High precision measurements

• Automatic report generation

• Automatic user-defined calculations

• Automatic identification of process cycles

• Creation of user-defined masters for spezific devices and thermal processes

• Three-dimensional demonstration of sensor placement

• FDA 21 CFR Part 11