1030W Aurora

OI Analytical Aurora 1030W TOC Analyzer

Total organic carbon (TOC), total inorganic carbon (TIC), and non-purgeable organic carbon (NPOC)

The Aurora 1030W TOC Analyzer processes aqueous samples for analysis of the total organic carbon (TOC), total inorganic carbon (TIC), and non-purgeable organic carbon (NPOC) content of the samples.

Aurora 1030C TOC Analyzer

OI Analytical Aurora 1030C TOC Analyzer

Analysis of Total Organic Carbon (TOC), Total Inorganic Carbon (TIC), and Non-Purgeable Organic Carbon (NPOC)

The Aurora 1030C TOC Analyzer processes aqueous samples for analysis of the total organic carbon (TOC), total inorganic carbon (TIC), and non-purgeable organic carbon (NPOC) content of the samples. Samples containing 100 ppb to 30,000 ppm of organic carbon can be analyzed. The Aurora 1030C supports USEPA-approved methods, Standard Methods, ASTM, DIN/ISO/CEN, and EU Methods. Depending upon the protocol employed, up to 300 samples per 24-hour period can be analyzed, and in excess of 100,000 samples per year.

OI Analytical 1088 Rotary TOC Autosampler

OI Analytical 1088 Rotary TOC Autosampler

Specifically designed to operate with an Aurora 1030 TOC analyzer

The 1088 Rotary Autosampler is specifically designed to operate with the Aurora 1030W TOC analyzer  or  Aurora 1030C TOC analyzer. The 1088 autosampler aspirates liquid samples from vials and transfers each sample aliquot to an Aurora 1030 TOC analyzer for analysis. A removable 88-position autosampler tray loads the sample vials for fully automated, unattended operation.

OI Analytical 1030S TOC Solids Analysis Module

OI Analytical 1030S TOC Solids Analysis Module

Sample preparation module enabling the analysis of TOC or TC content in solid materials.

The 1030S Solids Module is a sample preparation module enabling the analysis of the total organic carbon (TOC) or total carbon (TC) content in solid materials. The 1030S module is operated in conjunction with an Aurora 1030W or 1030C TOC analyzer.

OI Analytical Flow Solution™ FS 3700 Automated Chemistry Analyzer

OI Analytical Flow Solution™ FS 3700 Automated Chemistry Analyzer

Improved laboratory productivity with automated wet chemistry test procedures

The FS 3700 Automated Chemistry Analyzer is an advanced continuous flow analyzer designed to improve laboratory productivity by automating wet chemistry test procedures.

OI Analytical Eclipse 4660 Purge-and-Trap Sample Concentrator

OI Analytical Eclipse 4660 Purge-and-Trap Sample Concentrator

The Gold Standard In Volatiles Analysis

The Eclipse 4660 Purge-and-Trap Sample Concentrator processes samples for analysis of volatile organic compounds (VOCs) by gas chromatography (GC) or gas chromatography/mass spectrometry (GC/MS). Innovative, patented components within the Eclipse significantly improve sample processing steps of the purge-and-trap technique. 

OI Analytical 4100 Water/Soil Sample Processor

OI Analytical 4100 Water/Soil Sample Processor

Advanced Sample Processing for VOC Analysis

The OI Analytical 4100 Water / Soil Sample Processor automates the handling and processing of samples in 40-mL VOA vials for purge-and-trap analysis of volatile organic compounds (VOCs) in accordance with U.S. EPA methods. The 4100 efficiently processes up to 100 drinking water, wastewater, or soil samples and operates with a single or dual Eclipse 4660 purge-and-trap instruments.

OI Analytical 4551A Purge-and-Trap Water Autosampler

OI Analytical 4551A Purge-and-Trap Water Autosampler

For analysis of VOCs in clean or lightly particulated water samples.

The M4551A Purge-and-Trap Water Autosampler achieves results by automating VOC analysis of up to 51 samples. Vertical docking of the autosampler to the Eclipse 4660 Sample Concentrator means no extra benchspace is used. The removable, lightweight sample carousel makes sample loading and unloading easy, while its spiral design optimizes septum-piercing accuracy. With its proven, reliable sample handling system, the Model 4551A gets the job done, sample after sample.

LV 20

OI Analytical LV-20 Standards Addition Module

Minimize standard usage and decrease laboratory operating costs for expensive standards

The LV-20 Standards Addition Module is an option for the 4551A Purge-and-Trap Autosampler that injects programmed volumes (1, 2, 5, 10, or 20 microliters) of internal standard, surrogate or matrix spike standards to improve the accuracy and precision of GC-GC-MS analyses.

PFPD 5383 controller and sensor

OI Analytical Pulsed Flame Photometric Detector (PFPD)

Optimizing selective detection of sulfur, phosphorus, and 26 other compounds.

OI Analytical's patented* Model 5380 Pulsed Flame Photometric Detector (PFPD) represents the latest advance in flame photometric detector design, optimizing selective detection of sulfur, phosphorus, and 26 other compounds.

OI Analytical 9210p On-line TOC Analyzer

OI Analytical 9210p On-line TOC Analyzer

Designed to continuously monitor TOC levels in process water streams

The OI Analytical 9210p On-line Total Organic Carbon (TOC) Analyzer is designed to continuously monitor TOC levels in process water streams. The 9210p uses proven heated persulfate oxidation technology for accurate, dependable operation and regulatory compliance. Virtually all organic compounds dissolved in water can be oxidized with high efficiency by this technique.

OI Analytics CNSolution™ 9310 On-line Cyanide Analyzer

OI Analytics CNSolution™ 9310 On-line Cyanide Analyzer

Accurate measurement of Cyanide in precious metal leaching solutions

The OI Analytical CNSolution™ 9310 On-line Cyanide Analyzer is designed to measure available cyanide in precious metal leaching solutions by U.S. EPA Method OIA-1677 and ASTM D 6888-09. The gas-diffusion amperometry technique in these methods has been demonstrated to be free of interferences from copper and metallic sulfides that impair the accuracy of traditional techniques such as titration.

OI Analytical 4760

OI Analytical Eclipse 4760 Purge-and-Trap Sample Concentrator

The Gold Standard In Volatiles Analysis

The Eclipse 4760 Purge and Trap Sample Concentrator sets a new standard for ease-of-use for volatile organic compound (VOC) analysis. The new 4th generation system includes the popular features from the Eclipse platform that chemists around the world rely on for accurate, dependable results along with technology enhancements, intuitive software, and a slim-line, open architecture design that saves bench space and allows easy access to components.